Digital conference system enables meetings of up to 3,800 users to be managed with complete control and reliability. Features include digital audio transmission, interpretation of up to 31 languages, and SW 6000 to provide extensive software support.
Main Features
Main Features
- Fully digital audio transmission
- Expandable up to 3,800 delegate units (with additional equipment)
- Accommodates simultaneous interpretation of up to 31 languages
- Support for 4 microphone operation modes: Automatic, First-On/First-Off, Manual, and VOX (voice activation)
- Control the system with tablet or PC through web browser interface or an external room control system
- SW 6000 provides extensive software options to support voting, agenda management, ID card registration, recording/archiving, video projection, reporting, and more
Description
Clarity, precision and reliability
The DCS 6000 Digital Conference System combines microphone handling, voting, conference management, and interpretation in one integrated system. A variety of touchscreen, portable, and flush mounted conference units offer solutions for temporary meetings and permanently-installed systems. A comprehensive suite of powerful software options (SW 6000) make it easy to manage every aspect of the conference, from audio, to voting, to recording and archiving.
The DCS 6000 is the ideal audio solution for large meetings held by:
- National, state, or local legislative bodies
- Government or regulatory agencies
- Corporations, organisations, or associations
- Educational institutions
Components
Components
Specs
Specs
Technical specifications
Further Technical Specifications
- Conforms to: IEC 60914, PS CU approvals CE, KC, CCC, cULus, TÜV
- Supply voltage: For CU 6105 48V/3A
System Performance
The following table provides maximum number unit and channel counts per DCS 6000 system. (requires FL6000)
Audio
- Max. number of discussion units: 250
- Number of discussion units powered by DIS-CCU : up to 60
- Max. number of open "floor" microphones: 8
- Max. number of languages (interpreter channels) : 2
- Max. number of interpreter units : 32
- Max. number of discussion units: 3800
- Number of discussion units powered by DIS-CCU : up to 46
- Max. number of open "floor" microphones: 8
- Max. number of languages (interpreter channels) : 31
- Max. number of interpreter units : 200
- DCS-LAN outputs : Four (4) RJ45 female sockets
- TCP/IP : RJ45 female sockets
Audio Inputs
- Analog Input 1 : One 3-pin female XLR socket (electronically balanced)
- Nominal input level (Input 1) : switchable ( 0 dBm (0.775V RMS, -10 dBm (0.245V RMS)
- Max. input level : +15 dBm (4.5V RMS)
- Input Impedance : 50-100 kΩ
- Analog Input 2 (Audio In or EEM ) : One 3-pin female XLR socket (electronically balanced) with contact closure
Audio outputs
- Analog audio out : Eight (8) 3-pin male XLR sockets (electronically balanced)
- Maximum load : > 1 k ohm
- Nominal output level : 0 dBm at nominal input
- Max. output level : 4.9V RMS ~ +16 dBm
Electrical
- Power consumption : 22W/48V (150W max.)
- Supply voltage for microphone units : 122W/48V
- Sound quality : 24 bit audio, 32 kHz sampling frequency
- Frequency response : 65 Hz-16 kHz
- THD : < 0.1 %
- Signal-to-noise ratio : > 85 dBA
Mechanical
- Mounting : tabletop, standard 19" rack
- Dimensions (H x W x D) : ( 44.4 x 426 x 186 mm ),( 1.75 x 16.8 x 7.2 in. )
- Color : Black
- Weight : 2.8 kg (6.17 lbs. )
- Temperature range - Operation : 5° to 40° C, 35-80% humidity
- Temperature range - Storage: -20° to 60° C, 10-80% humidity
PS CCU External Power Supply (SUR-A15T)
- Main voltage : 100-240 V, 50-60 Hz nominal
- Max. consumption : 175 W
- Total supply power : 144 W (power factor: >0.95)
- Standby consumption : <0.15 W (no load)
- Supply voltage : 48V/3A @ 40°C ( De-rate linearly to 50% @ 60°C )
- Efficiency : 89%, typical
- Inrush Current : 230 V: <80 A , 115 V: <40 A
Certifications: The DCS 6000 system conforms to standard IEC 60914.